Investigating the effect of thermal loading on geothermal piles in stratified soils

نوع مقاله : مقاله پژوهشی‌

نویسندگان
1 Assistant Professor, Department of Civil Engineering, Faculty of Engineering, Qom University of Technology, Qom, Iran
2 Master of Civil Engineering, Department of Civil Engineering, Faculty of Engineering, Qom University of Technology, Qom, Iran
چکیده
Energy pile is a type of foundation that simultaneously provides the two goals of structural load transfer and energy conversion. In addition to transferring the structural load of the building to the lower layers, this system also acts as a heat exchanger. In this article, to investigate the effect of soil and geothermal pile on each other, numerical modeling was performed using finite element method using COMSOL software. The main purpose of this study is to investigate the response of geothermal pile in layered soils and compare it with geothermal pile implemented in homogeneous soil. This problem has been performed considering the different soil layers that are on the bedrock and the results have been compared with the experimental data of the geothermal pile placed in the layered soil. The results showed that the properties of soils and the location of loose and dense
layers in the depth of the soil have a significant effect on the type of behavior of the pile, so the deformations and stresses obtained from the numerical analyzes are related to the modulus of
elasticity and in other words, to the hardness of the soil. It conducted that the value of the strain obtained from the numerical analysis of the pile placed in multi-layered soil is between the value of the pile strains in the case where the homogeneous soil is only loose or dense. The conclusion of obtained results is that the vertical stresses and strains of the pile placed in multi-layered soil at the depth of the earth's surface are in better agreement with the vertical stresses and strains of the pile placed in loose soil. The modulus of elasticity of soil with average density of type 2 is 74% higher than the modulus of elasticity of loose soil considered in the analysis, which has led to a 27%
reduction in displacement, a 40% increase in compressive stress and a 77% reduction in vertical strain. The same change in the modulus of elasticity of the soil layers caused a change in the values of stresses and pile stresses in the state of layered soil. Also, the 40% change in the modulus of elasticity of type 2 and 3 soils has caused the amount of displacement to decrease by 17% and the amount of compressive stress and strain to increase by 11% and decrease by 27%, respectively. The results of the numerical analysis showed that the type of soil and the way it is located in the depth have a significant effect on the behavior of the geothermal pile.
 
کلیدواژه‌ها

موضوعات


عنوان مقاله English

Investigating the effect of thermal loading on geothermal piles in stratified soils

نویسندگان English

Masoud Amelsakhi 1
Fatemeh Sheshpari 2
1 Master of Civil Engineering, Department of Civil Engineering, Faculty of Engineering, Qom University of Technology, Qom, Iran
2 Master of Civil Engineering, Department of Civil Engineering, Faculty of Engineering, Qom University of Technology, Qom, Iran
چکیده English

Energy pile is a type of foundation that simultaneously provides the two goals of structural load transfer and energy conversion. In addition to transferring the structural load of the building to the lower layers, this system also acts as a heat exchanger. In this article, to investigate the effect of soil and geothermal pile on each other, numerical modeling was performed using finite element method using COMSOL software. The main purpose of this study is to investigate the response of geothermal pile in layered soils and compare it with geothermal pile implemented in homogeneous soil. This problem has been performed considering the different soil layers that are on the bedrock and the results have been compared with the experimental data of the geothermal pile placed in the layered soil. The results showed that the properties of soils and the location of loose and dense
layers in the depth of the soil have a significant effect on the type of behavior of the pile, so the deformations and stresses obtained from the numerical analyzes are related to the modulus of
elasticity and in other words, to the hardness of the soil. It conducted that the value of the strain obtained from the numerical analysis of the pile placed in multi-layered soil is between the value of the pile strains in the case where the homogeneous soil is only loose or dense. The conclusion of obtained results is that the vertical stresses and strains of the pile placed in multi-layered soil at the depth of the earth's surface are in better agreement with the vertical stresses and strains of the pile placed in loose soil. The modulus of elasticity of soil with average density of type 2 is 74% higher than the modulus of elasticity of loose soil considered in the analysis, which has led to a 27%
reduction in displacement, a 40% increase in compressive stress and a 77% reduction in vertical strain. The same change in the modulus of elasticity of the soil layers caused a change in the values of stresses and pile stresses in the state of layered soil. Also, the 40% change in the modulus of elasticity of type 2 and 3 soils has caused the amount of displacement to decrease by 17% and the amount of compressive stress and strain to increase by 11% and decrease by 27%, respectively. The results of the numerical analysis showed that the type of soil and the way it is located in the depth have a significant effect on the behavior of the geothermal pile.
 

کلیدواژه‌ها English

Geothermal energy pile
FEM
COMSOL
renewable energy
Bodas Freitas, T. M., Cruz Silva, F., and Bourne-Webb, P. J., 2013, The response of energy foundations under thermo-mechanical loading: Proceeding of the 18th International Conference of Soil Mechanics and Geotechnical Engineering, Paris.
Brandl, H., 2006, Energy foundations and other thermo-active ground structures: Géotechnique, 56(2), 81-122.
Cossel, A., 2019, Analytical solutions for thermo-mechanical soil structure interaction in energy piles: M.Sc. thesis, Kansas State University.
Dupray, F., Laloui, L., and Kazangba, A., 2014, Numerical analysis of seasonal heat storage in an energy pile foundation: Computers and Geotechnics, 55(1), P67-77.
Fang, J., Kong, G., and Yang, Q., 2022, Group performance of energy piles under cyclic and variable thermal loading: International Journal of Geomechanics, 148(8).
Goode, J. C., Zhang, M., and McCartney, J. S., 2014, Centrifuge modelling of energy foundations in sand, in Gaudin, C., and White, D., eds., Physical Modeling in Geotechnics: Proceedings of the 8th international conference on physical modelling in geotechnics. Perth, Australia, 14–17 January, Taylor and Francis, London, 729–736
Guo, Y., Zhang, G., Liu, S., Du, Y., and Liu, Z., 2018, Numerical study on the long-term thermal performance and ground temperature variation of energy pile in multi-layered soil: Energy Geotechnics, 90–96, doi: 10.1007/978-3-319-99670-7_12.
Houston, S. L., Dye, H. B., Lingnau, B., and Houston, W. N., 2015, Thermally-induced settlements for heat generating structures on unsaturated soils: Geotechnical and Geological Engineering, 33, 307–319
Laloui, L., Nuth, M., and Vulliet, L., 2006, Experimental and numerical investigations of the behaviour of a heat exchanger pile: International Journal for Numerical and Analytical Methods in Geomechanics, 30(8), 763–781.
Li, Q., Chen, L., and Qiao, L., 2017, Thermal effect on structural interaction between energy pile and its host soil: Advances in Materials Science and Engineering, https://doi.org/10.1155/2017/7121785.
McCartney, J. S., Rosenberg, J. E., and Sultanova, A., 2010, Engineering performance of thermo-active foundation systems, in Goss, C. M., Kerrigan, J. B., Malamo, J., McCarron, M. O., and Wiltshire, R. L., eds., GeoTrends: the Progress of Geological and Geotechnical Engineering in Colorado at the Cusp of a New Decade (GPP 6), 27–42.
Ng, C. W. W., Ma, Q. J., and Gunawan, A., 2016, Horizontal stress change of energy piles subjected to thermal cycles in sand: Computers and Geotechnics, 78, 54-61, http://dx.doi.org/10.1016/j.compgeo.2016.05.003.
Nguyen, V. T., Tang, A. M., and Pereira, J. M., 2017, Long-term thermo-mechanical behavior of energy pile in dry sand: Acta Geotechnica, 12(4), 729–737, doi:10.1007/s11440-017-0539-z.
Peric, D., Cossel, A. E., and Sarna, S. A., 2020, Analytical solutions for thermo-mechanical soil structure interaction in end-bearing energy piles: Journal of Geotechics and Geoenvironment, 146(7), 04020047.
Saggu, R., and Chakraborty, T., 2015, Cyclic thermo-mechanical analysis of energy piles in sand: Geotechnical and Geological Engineering, 33(2), 321-342.
Sani, A. K., and Singh, R. M., 2018, Response of unsaturated soils to heating of geothermal energy pile: Renewable Energy, 147(2), 2618-2632.
Sheshpari, F., 2018, Energy pile response under thermal load in different types of soil: MSc. Thesis, Qom University of Technology, (in Persian).
Wang, B., Bouazza, A., and Haberfield, C., 2011, Preliminary observations from laboratory scale model geothermal pile subjected to thermo-mechanical loading: Geo-Frontiers ASCE, Dallas, Texas, March 13–16, 430–439.